{"id":242,"date":"2016-07-15T10:10:51","date_gmt":"2016-07-15T10:10:51","guid":{"rendered":"http:\/\/www.gaudi.ch\/OpenDrop\/?p=242"},"modified":"2016-07-15T10:27:46","modified_gmt":"2016-07-15T10:27:46","slug":"microfluidics-congress-notes","status":"publish","type":"post","link":"http:\/\/www.gaudi.ch\/OpenDrop\/?p=242","title":{"rendered":"Microfluidics Congress Notes"},"content":{"rendered":"<p>Luis Ruben Soenksen just came back from the the <a href=\"http:\/\/www.globalengage.co.uk\/microfluidics-usa.html\">Global Engage Microfluidics Congress in Philadelphia<\/a> and here is waht he saw is relevant for our community:<\/p>\n<div class=\"gmail_default\">\n<ol>\n<li>Digital microfluidics is definitely a cool topic (but not the most popular)<\/li>\n<li>Droplet based microfluidics is super hype right now. Pico-liter and nano-liter droplets for single cell analysis and other things are what people want now. The microfluidics, biology and medical community see a lot of value on being able to handle drops from 20ul down to 1 picoliter. A device incapable of being scaled down to these sizes is not going to be competitive.<\/li>\n<li>Cost and long term scalability is a main concern, and that\u2019s where the strength of <a href=\"http:\/\/www.gaudi.ch\/OpenDrop\/?p=17\">this project<\/a> has it\u2019s greatest value (I think), the EWOD approach with a <a href=\"http:\/\/www.gaudi.ch\/OpenDrop\/?p=116\">cartridge<\/a> is for SURE the right way to go.<\/li>\n<li>High Speed on moving droplets, easy multiplexing, and high end stimulation and <a href=\"http:\/\/www.gaudi.ch\/OpenDrop\/?p=162\">sensing<\/a> (electrical &amp; optical) capabilities is something that we need to incorporate sooner rather than later consider for example Professor Richard Fair from Duke (<a href=\"http:\/\/microfluidics.ee.duke.edu\" target=\"_blank\">http:\/\/microfluidics.ee.duke.edu<\/a>) he sold his system to Illumina because of this to do a pathogen sensitivity platform.<\/li>\n<li>Other people to watch is this group from Harvard led by Prof. Robert M. Westervel. These guys are heavy on electronics and have something that I find amazing (<a href=\"http:\/\/meso.seas.harvard.edu\/digitalmicrofluidics.html\" target=\"_blank\">http:\/\/meso.seas.harvard.edu\/digitalmicrofluidics.html<\/a>) They use something like a CCD to do this via\u00a0dielectrophoresis (DEP) and using an inmisible phase such as oil, I think we can do EWOD the same way, we just need to find a cheap multi-electrode array to use. Also if we go down to smaller scale electrodes the force needed to move a drop decreases which can enable us to go down in voltage and to use cheaper surface coatings that are more scalable and robust.<\/li>\n<\/ol>\n<div>The review\u00a0 &#8220;<a href=\"http:\/\/www.ncbi.nlm.nih.gov\/pubmed\/27272540\">digital microfluidics as portable platforms for lab-on a-chip applications<\/a>&#8221; that was published very recently, I think is a good way to get a sense of what is really valuable and a way to really move forward on this.<\/div>\n<\/div>\n<p>&nbsp;<\/p>\n<p>Thank you Luis for sharing.<\/p>\n","protected":false},"excerpt":{"rendered":"Luis Ruben Soenksen just came back from the the Global Engage Microfluidics Congress in Philadelphia and here is waht he saw is relevant \n<a class=\"moretag\" href=\"http:\/\/www.gaudi.ch\/OpenDrop\/?p=242\"> <font color=\"#fa5742\"> More...<\/font><\/a>","protected":false},"author":1,"featured_media":244,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[7],"tags":[],"class_list":["post-242","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-research"],"_links":{"self":[{"href":"http:\/\/www.gaudi.ch\/OpenDrop\/index.php?rest_route=\/wp\/v2\/posts\/242","targetHints":{"allow":["GET"]}}],"collection":[{"href":"http:\/\/www.gaudi.ch\/OpenDrop\/index.php?rest_route=\/wp\/v2\/posts"}],"about":[{"href":"http:\/\/www.gaudi.ch\/OpenDrop\/index.php?rest_route=\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"http:\/\/www.gaudi.ch\/OpenDrop\/index.php?rest_route=\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"http:\/\/www.gaudi.ch\/OpenDrop\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=242"}],"version-history":[{"count":2,"href":"http:\/\/www.gaudi.ch\/OpenDrop\/index.php?rest_route=\/wp\/v2\/posts\/242\/revisions"}],"predecessor-version":[{"id":245,"href":"http:\/\/www.gaudi.ch\/OpenDrop\/index.php?rest_route=\/wp\/v2\/posts\/242\/revisions\/245"}],"wp:featuredmedia":[{"embeddable":true,"href":"http:\/\/www.gaudi.ch\/OpenDrop\/index.php?rest_route=\/wp\/v2\/media\/244"}],"wp:attachment":[{"href":"http:\/\/www.gaudi.ch\/OpenDrop\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=242"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"http:\/\/www.gaudi.ch\/OpenDrop\/index.php?rest_route=%2Fwp%2Fv2%2Fcategories&post=242"},{"taxonomy":"post_tag","embeddable":true,"href":"http:\/\/www.gaudi.ch\/OpenDrop\/index.php?rest_route=%2Fwp%2Fv2%2Ftags&post=242"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}